Filter Results By:

Products

Applications

Manufacturers

Showing results: 31 - 45 of 46 items found.

  • Magnetic Material Test Fixture

    16454A - Keysight Technologies

    The 16454A is designed for accurate permeability measurements of toroidal-shaped magnetic materials. Since the construction of this fixture creates one turn around the toroid (with no magnetic flux leakage), the need of winding a wire around the toroid is unnecessary. Complex permeability is calculated from the inductance with and without the toroid. When the E4991A/4291B with option 002 is used as the measurement instrument, direct readouts of complex permeability are possible. In addition, it is furnished with a small and a large fixture to adapt to a wide range of sizes.

  • Digital Teslameters/Gaussmeters

    Group3 Technology

    S Digital Teslameters offer accurate, high resolution measurement of magnetic flux densities, withdirect digital readout in tesla or gauss, and serialcommunications by fiber optics or RS-232C for system applications.The instruments are light and compact, and the probes are easy to use. The DTM-151 has been engineered to withstandthe severe electrical interference produced by high voltage discharge.

  • Custom Magnetic Recording Heads

    International Electro-Magnetics, Inc.

    We have manufactured over 5,000 different head designs. If we don't have one to suit your requirements, we will design and build to your specification. Our toolroom is well equipped to produce precision parts, and our design projects have included flux sensing systems, magnetic disk encoding, and electronic test equipment.

  • Advanced Tachometer

    FT-2500 - Ono Sokki

    FT-2500 advanced tachometer measures the rotational speed by using the signal of change in sound, vibration or magnetic flux from rotating machines such as motor or the like.The use of FFT technology enables the FT-2500 to calculate and display the rotational speed of any complex waveform signals from microphone, sound level meter or vibration sensor by extracting the frequency component which is equivalent to the rotational speed.

  • Diesel Engine Tachometer

    GE-2500 - Ono Sokki

    The GE-2500 diesel engine tachometer uses rotation speed of an alternator to measure engine rotation speed. With FFT calculation, this tachometer achieves reliable and stable measurement for both diesel and gasoline engines.The OM-1500 is a compact type detector designed for measuring rotation speed of an alternator. It detects magnetic flux leakage from an alternator. It is used to combine with the GE-2500. (The OM-1200 can also be used with the GE-2500.)

  • Helmholtz Coil

    Ferrites India

    In the measurement of magnetic fields by means of Hall probes or measuring coils it is necessary to calibrate the instruments in a known magnetic field. Our standard field coil according to Helmholtzenables to production of a magnetic field calculable with high accuracy from the dimensions and the amperage. In series arrangement with an accurate ammeter field strengths of up to 800A/cm are produced. The dield room accessible both in axial and radial direction. Helmholtz coils with fluxmeters are also useful in testing of magnets. Helmholtz coils give repeatable results as against the search coils due to which the magnets can be compared with more accuracy for their total flux and in turn their quality. Field Generating and Field Detecting Helmholtz coils are designed as per user specifications.

  • Gaussmeter/Teslameter

    Model 2100 - Magnetic Instrumentation Inc.

    The Model 2100 Gaussmeter is a fully featured, high-end Gaussmeter with a low cost Gaussmeter price. It is a compact, high accuracy, microprocessor controlled, flux density measuring instrument. The Model 2100 is capable of measuring static (DC), alternating (AC), or pulsed magnetic fields. Twelve measurement ranges allow the operator to configure the meter for maximum resolution and accuracy from 300mG (30 microTesla) to 300 kG (30 Tesla). Selecting primary measurement functions is quick and easy with dedicated front panel function keys. An easy-to-use menu allows access to user defined parameters such as upper and lower magnetic limits and relative magnetic measurements. Remote meter configuration is completely accessible using the built in RS-232 Interface or optional IEEE-488 Interface.

  • Magnetic Field And Permeability Measurement

    MAGNETOMAT 1.790 - Foerster Instruments, Incorporated

    The MAGNETOMAT 1.790 is a measuring system for the precision detection of magnetic flux density and relative permeability. The MAGNETOMAT software is used for displaying the measured values and saving and exporting data. The wide range of probes facilitates optimal adjustment to the conditions of the application, such as the measurement of relative permeability within the scope of the quality control of stainless steel and low-permeable (non-magnetic) alloys. Further applications include the long-term monitoring of the magnetic environment, e.g. prior to installing magnetically sensitive devices, and the localization of ferrite enclosures in stainless steel and NE materials. Changes in material (sulfidation, degradation of lamination, structural changes) can also be proven thanks to permeability comparative measurements.

  • Hall Effect Measurement system

    HMS-3300 - ECOPIA

    Magnetic flux density : 0.55Tesla (+/-0.03T)Gap distance between both round magnets : 26mm / Round magnet diameter : 50mmMeasurable temp : RT ~ 300℃(model# HT55T3). Resolution : 0.1℃(Model# HT55T5 : RT ~ 500℃)Both HT55T3 and HT55T5 are only capable of using with HMS-3000 main body.(Not compatible with HMS-5000 )- You can flow purge gas into small chamber and measure hall effect at the same time. Gas control valve can be installed as an option.

  • Motor/Gasoline Engine RPM Detector

    OM-1500/1200 - Ono Sokki

    The OM-1500/1200 motor/gasoline engine RPM detector is designed for rotation measurement of a gasoline engine and an EV/HEV motor. It detects magnetic flux leakage from the motor itself or the engine’s ignition coil.This easy to use and durable detector can measure engine rotation by attaching in parallel with the ignition coil. When the EV/HEV motor rotation is measured, attach the OM-1500/1200 perpendicular to the motor rotating shaft.It is used with the engine tachometer by Ono Sokki (GE-2500, AR-7240B, CT-6520B, HT-6200, SE-1620, FT-2500, FT-7200).

  • Fluxmeter

    480 - Oersted Technology

    The Model 480 is a laboratory grade fluxmeter, for use with a Helmholtz coil or custom search coils. This instrument measures the total flux of a magnet part, which can be related to the magnetic field strength. Applications include magnet testing, magnetizing, and automated field measurement. In order to provide accurate and repeatable measurements, automatic or manual drift compensation is available to the user. A peak mode allows even the fastest magnetic pulse, such as those from a magnetizer, to be accurately measured. The Model 480 is also useful for measuring AC fields that are too high in frequency for a gaussmeter to detect. Relay outputs and an external reset input allow for simple automation functions to be implemented, while the RS232C and IEEE-488 ports permit advanced control of the fluxmeter via a remote computer or automation equipment.

  • Digital Tesla Meter

    HT208 - Rinch Industrial Co.,Limited

    Model HT208 digital teslameter is controlled by the SCM,which is suitable for handle operation.It can be used to measure DC or AC magnetic field and flux dencity.The device can be carried on one’sperson. It is characterized by its wide measuring range,simple operation and clear display. It is still added with the function of maintenance such as holding Measure Value/Peak Value,As mT or Gs unit of display can be change over,Measuring range of 200mT or 2000mT can be choosed,and others that as reseting zero by key and so on. The power is one piece of battery 9V. It can be used continually about 20 hours

  • Hall Effect Measurement system

    HMS-3000 - ECOPIA

    Hall Effect Measurement System is very useful for measuring Carrier Concentration, Mobility, Resistivity and Hall Coefficient that should be pre-checked in order to grasp the electrical specifications of semiconductor device. Therefore, it is essentially required system to understand the electrical characteristics of semiconductor device.Ecopia’s HMS series consist of constant current source , terminal conversion system by Van der Pauw technique, low temperature(77K) test system and magnetic flux density input system. So, it is well-established system that has all the things needed to Hall Effect Measurement System.

  • Advanced Handheld Tachometer

    FT-7200 - Ono Sokki

    The FT-7200 Advanced Tachometer is an easy-to-use handheld digital tachometer offering high functions and performance. The use of FFT (Fast Fourier Transform) technology enables the FT-7200 to perform frequency analysis of rotation speed by using change of signal in sound, vibration or magnetic flux from rotating machines such as a motor or the like. Selection from 5 kinds of measurement modes allows it to calculate and display rotation speed of any complex waveform signals from a sound level meter or an accelerometer accurately by extracting the exact frequency component.

  • Magnetic Field and Permeability Measurement

    MAGNETOSCOP® 1.070 - Foerster Instruments, Incorporated

    The MAGNETOSCOP 1.070 is a portable magnetometer system with microprocessor and probes for measuring the magnetic flux density as an absolute or differential value (gradient). It has a USB port for simple data transfer and an SD card for saving measurement data and parameters. The measuring system also facilitates the recognition and saving of peak values and the adjustment of thresholds for limit values. The unit can be used for series and individual measurements. The data can be easily analyzed and documented with the PC software included in the scope of delivery. The MAGNETOSCOP 1.070 thus facilitates the portable and fast measurement of the relative permeability within the scope of the quality control of stainless steel and low-permeable (non-magnetic) alloys as well as the localization of ferrite enclosures. Changes in material (sulfidation, degradation of lamination, structural changes) can also be proven thanks to permeability comparative measurements.

Get Help